Blue-Light Exposure in Dental Photopolymerization: Ocular, Thermal, and Occupational Safety Considerations for Contemporary Light-Curing Units: Review Article
DOI:
https://doi.org/10.65795/vx46dz66Keywords:
blue light hazard, dental light-curing unit, LED photopolymerization, occupational safety, pupl temperature, protective eyewear, retinal phototoxicityAbstract
Dental light-curing units are indispensable for the polymerization of resin-based restorative materials, adhesives, sealants, luting agents, and orthodontic bonding systems. The progression from quartz-tungsten-halogen technology to high-intensity light-emitting diode systems has improved photopolymerization efficiency, but it has also increased operator and patient exposure to concentrated blue-violet radiation and procedure-related heat. To provide a structured review of the optical and thermal hazards associated with contemporary dental light-curing units, with emphasis on retinal phototoxicity, soft-tissue and pulpal heating, protective eyewear, and chairside risk mitigation. A structured narrative review was performed to assess the ocular and thermal hazards associated with contemporary dental light-curing units. A systematic literature search was conducted using PubMed, Scopus, and Google Scholar databases for publications between 2000 and 2024. Search keywords included “dental light-curing units,” “blue light hazard,” “retinal phototoxicity,” “LED curing lights,” “pulpal temperature rise,” and “occupational exposure in dentistry.” Inclusion criteria comprised in vitro studies, clinical investigations, review articles, and international safety guidelines focusing on optical radiation hazards, thermal effects, and protective strategies in dentistry. Articles not published in English or lacking direct relevance to dental photopolymerization were excluded. A total of 45 studies were initially identified, of which 20 relevant articles were included following title screening, abstract evaluation, and full-text assessment. Data were analyzed qualitatively to synthesize current evidence on biological risks and clinical safety protocols. Most contemporary curing units emit predominantly within the 400–500 nm spectrum, with the greatest retinal blue-light hazard reported around 420–455 nm. Modern LED devices commonly deliver irradiance two to three times greater than earlier quartz-tungsten-halogen units, and some high-power units have claimed outputs approaching 5,000 mW/cm². Repeated direct or reflected exposure may contribute to cumulative retinal photochemical injury, whereas prolonged irradiation, inadequate tip positioning, and misuse can elevate pulpal and soft-tissue temperatures sufficiently to increase the risk of biological injury. Blue-light curing should be regarded not only as a materials-processing step but also as an occupational and patient-safety issue. Clinical safety depends on wavelength-compatible eye protection, strict adherence to manufacturer instructions, routine output monitoring, and procedural techniques that minimize unnecessary ocular and thermal exposure.
Downloads
References
Price RBT, Ferracane JL, Shortall AC. Light-curing units: A review of what we need to know. J Dent Res. 2015;94(9):1179-1186.
Rueggeberg FA, Giannini M, Arrais CAG, Price RBT. Light curing in dentistry and clinical implications: A literature review. Braz Oral Res. 2017;31(suppl 1): e61.
Jandt KD, Mills RW. A brief history of LED photopolymerization. Dent Mater. 2013;29(6):605-617.
Youssef PN, Sheibani N, Albert DM. Retinal light toxicity. Eye (Lond). 2011;25(1):1-14.
Price RB, Labrie D, Bruzell EM, Sliney DH, Strassler HE. The dental curing light: A potential health risk. J Occup Environ Hyg. 2016;13(8):639-646.
Fluent MT, Ferracane JL, Mace JG, Shah AR, Price RBT. Shedding light on a potential hazard: Dental light-curing units. J Am Dent Assoc. 2019;150(12):1051-1058.
Bruzell EM, Johnsen B, Aalerud TN, Christensen T. Evaluation of eye protection filters for use with dental curing and bleaching lamps. J Occup Environ Hyg. 2007;4(6):432-439.
Soares CJ, Rodrigues MP, Vilela AB, et al. Evaluation of eye protection filters used with broad-spectrum and conventional LED curing lights. Braz Dent J. 2017;28(1):9-15.
Labrie D, Moe J, Price RB, Young ME, Felix CM. Evaluation of ocular hazards from 4 types of curing lights. J Can Dent Assoc. 2011;77:b116.
Rassaei M, Thelen M, Abumuaileq R, Hescheler J, Lüke M, Schneider T. Effect of high-intensity irradiation from dental photopolymerization on the isolated and superfused vertebrate retina. Graefes Arch Clin Exp Ophthalmol. 2013;251(3):751-762.
Maucoski C, Zarpellon DC, Dos Santos FA, et al. Analysis of temperature increase in swine gingiva after exposure to a Polywave LED light curing unit. Dent Mater. 2017;33(11):1266-1273.
Zarpellon DC, Runnacles P, Maucoski C, Coelho U, Rueggeberg FA, Arrais C. Controlling in vivo, human pulp temperature rise caused by LED curing light exposure. Oper Dent. 2019;44(3):235-241.
Tosini G, Ferguson I, Tsubota K. Effects of blue light on the circadian system and eye physiology. Mol Vis. 2016;22:61-72.
International Electrotechnical Commission. IEC 62471:2006. Photobiological safety of lamps and lamp systems. Geneva: IEC; 2006.
International Organization for Standardization. ISO 10650:2018. Dentistry—Powered polymerization activators. Geneva: ISO; 2018.
International Organization for Standardization. ISO 12609-1:2013. Eyewear for protection against intense light sources used on humans and animals for cosmetic and medical applications—Part 1: Specification for products. Geneva: ISO; 2013.
American National Standards Institute/International Safety Equipment Association. ANSI/ISEA Z87.1-2015. Eye and face protection devices. Arlington, VA: ISEA; 2015.
United States Department of Labor, Occupational Safety and Health Administration. Standard 1926.102(a)(1): Eye and face protection. Washington, DC: OSHA; 2016.
United States Department of Labor, Occupational Safety and Health Administration. Standard 1910.133: Personal protective equipment—Eye and face protection. Washington, DC: OSHA; 2016.
Council on Dental Materials, Instruments, and Equipment. The effects of blue light on the retina and the use of protective filtering glasses. J Am Dent Assoc. 1986;112(4):533-535.
Published
Issue
Section
License
Copyright (c) 2026 krishna kumar vaidya (Author); Dr. KEDAR S. Munnoli (Translator)

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright and Licensing
All articles published in Trends in Biomaterials and Artificial Organs are published Open Access. To ensure the widest possible dissemination of research while protecting the integrity of the original work, we utilize the Creative Commons Attribution-NonCommercial-NoDerivs (CC BY-NC-ND) 4.0 International License.
User Rights
Under this license, the public is free to share (copy and redistribute the material in any medium or format) under the following terms:
- Attribution: Users must give appropriate credit, provide a link to the license, and indicate if changes were made.
- Non-Commercial: Users may not use the material for commercial purposes. This includes, but is not limited to, the sale of the article or its use in promotional materials for-profit.
- No Derivatives: If a user remixes, transforms, or builds upon the material, they may not distribute the modified material.
Author Rights
Authors retain copyright of their work while granting the journal a non-exclusive license to publish. Because of the NoDerivs (ND) and Non-Commercial (NC) designations:
- Third parties (such as other researchers) must seek permission from the authors/journal to include figures, tables, or portions of the text in new works or commercial publications.
- Authors may deposit the "Version of Record" in institutional repositories immediately upon publication, provided the CC BY-NC-ND 4.0 license is clearly linked.
How to Cite
Accepted 02-08-2026
Published 08-08-2026